On eBay Now...

Portable Medical Patient Monitor Vital Sign ICU ECG NIBP RESP TEMP SPO2 PR/HR US For Sale

Portable Medical Patient Monitor Vital Sign ICU ECG NIBP RESP TEMP SPO2 PR/HR US
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Buy Now

Portable Medical Patient Monitor Vital Sign ICU ECG NIBP RESP TEMP SPO2 PR/HR US:
$459.00

A.8 Inch Multi-parameter Monitor ICU CCU Vital Sign Dental Patient Monitor ECG NIBP RESP TEMP SPO2 HRDescription:

Dental Oral?implant?monitor can be used in oral implant surgery. It can monitor and measure human body's vital signs in real time for patients, especially patients with cardiovascular and cerebrovascular diseases and diabetes, and monitor the changes of life signs in real time, and provide basis for oral implant.

Features:

High brightness and high resolution display 8 inch color LCD screen ,more comfortable glare

7-Channel ECG Waveform display,5 minutes ECG waveform playback, automatic detection of ST segment

384 hours trend data memory for all the parameters and dynamic waveform capture

Can be arbitrarily set the alarm limit, automatic sound and light alarm

Anti-movement, anti-defibrillation, anti electrosurgical interference

Remote central monitoring network interface

Drug solubility calculation function, Arrhythmia analysis function

Built-in lithium battery, AC and DC, can provide long-term monitoring after power failure

Widely used in the Department of internal medicine,?Dntal practices (both pediatric and adult), oral surgery centers surgery, operation room,obstetrics and Gynecology, pediatrics, emergency center, ICU, CCU.

Standard configuration:

ECG, NIBP, SPO2, TEMP, RESP,

Technical parameters:

ECG Measurement:

Leads choices: All, I, II, III, aVF, aVR, aVL. V1--6 chest leads showed

Gains options:?? × 1, × 2, × 4, and × 0.5 four trenches

Frequency:

diagnosis? 0.05 ~ 130Hz

Monitoring? 0.5 ~ 40Hz

Operation 1~ 20Hz

Common-mode signal inhibition:

diagnosis? > 90 dB

Monitoring? > 100 dB

Operation > 100 dB

Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls.

HR range:

Adult :15?~?300bpm

Infants / children: 15?~?350 bpm

HR Accuracy: ± 1 bpm

Precision calibration signal: 1mv(peak, ± 5% accuracy)

ST Detection: measurement range (-2.0mV~+2.0mV)

Baseline recovery time: < 3 seconds after defibrillation

Alarm: Sound and Light

Preset heart rate range: (Alarm over preset numerical)

Ceiling:40~255 bpm adjustable

Threshold: 20~160 bpm adjustable

RESP Breath:

Breathing frequency range:

Adult : 7~120 brPM

Infants / children:7~150 brPM

Accuracy:± 2brpm

Gains options: × 1, × 2, × 4, and × 0.5 four trenches

Alarm: Sound and Light

Alarm range: (numerical preset alarm over)

Ceiling:?????? 10~100 bpm adjustable

Threshold:???? 0?~99 bpm adjustable

NIBP measurement:

Technology: Oscillometric

Mode: Manual / automatic / continuous

Measurement units: mmHg / kpa

Protection: Double security protection

Scope: Pressure Cuffs 0-250 mmHg

Overvoltage protection: Double safety protection

Adult Pattern:300 mmHg

Children Pattern:240 mmHg

Newborn Pattern:150 mmHg

Blood pressure measuring range:

Adult

Systolic blood pressure: 40~270 mmHg

Diastolic blood pressure: 10~215 mmHg

Pressure on the average: 20~235 mmHg

Children

Systolic blood pressure: 40~200 mmHg

Diastolic blood pressure: 10~150 mmHg

Pressure on the average: 20~165 mmHg

Newborn

Systolic blood pressure: 40~135 mmHg

Diastolic blood pressure: 10~100 mmHg

Pressure on the average: 20~110 mmHg

The accuracy of blood pressure:The maximum average error amp 5mmHg; maximum standard deviation 8mmHg

Alarm: Sound and Light

Preset range: report (Numerical exceed preset alarm)

Systolic blood pressure maximum: 40~250 mmHg adjustable

Threshold: 10~220 mmHg adjustable

Diastolic blood pressure ceiling: 20?~250 mmHg adjustable

Minimum standards: 10?~220 mmHg adjustable

Spo2 measurement

Range: 70~00%:±2DIGIT? 0~69%:Not defined

Resolution: 1%

Pulse frequency: 20~300 times / min

Alarm: Sound and Light

Preset range: report (Alarm over preset numerical)

Ceiling: 20%?~?100% adjustable

Threshold: 10%?~?99% adjustable

TEMP measurement:

Technology: thermostat temperature probe

Measuring range: 0°C~45°C

Temperature resolution: 0.1%

Accuracy: ± 1°C

Response Time: 1s

Alarm: Sound and Light

Preset range: report (numerical preset alarm over)

Maximum: 20.1°C~45?°?C adjustable

Threshold: 20°C~44.9°C Adjustable

Power:

AC power supply: AC 220V, 50Hz. 1A maximum current

Temperature: 5~40°C

Storage temperature: -20°C~40°C

Working humidity:?≤85% relative humidity, non-condensing

Humidity storage:?≤95% relative humidity, non-condensing

Altitude: 86~4106kpa feet (working condition)

Whole Power: not more than 70VA

Package Include:

1×Dental Patient Monitor

1×Cuff for adult

1×SpO2 Probe

1×5 lead EKG?Cable

1×Temperature Probe For ECG monitor

1×User Manual

?

B.10 Inch Multi-parameter Monitor ICU CCU Vital Sign Dental Patient Monitor ECG NIBP RESP TEMP SPO2 PRDescription:

Portable Dental Oral implant?Patient Monitor is adaptable to adult, pediatric and neonatal usage.It?can be used in oral implant surgery. It can monitor and measure human body's vital signs in real time for patients, especially patients with cardiovascular and cerebrovascular diseases and diabetes, and monitor the changes of life signs in real time, and provide basis for oral implant.

Features:

10 inch color high resolution TFT display.

Can be arbitrarily set the alarm limit, automatic sound and light alarm

Anti-movement, anti-defibrillation, anti electrosurgical interference

Remote central monitoring network interface

Drug solubility calculation function, Arrhythmia analysis function

Built-in lithium battery, AC and DC, can provide long-term monitoring after power failure

Widely used in the Department of internal medicine, Dental practices (both pediatric and adult), oral surgery centers surgery, operation room,obstetrics and Gynecology, pediatrics, emergency center, ICU, CCU.??

Standard configuration:

ECG, NIBP, SPO2, TEMP, RESP,PR

Specification:

ECG

Lead Mode:5 Leads (?R, L, F, N, C or RA, LA, LL, RL,V)

Lead selection:I, II, III, avR, avL, avF, V,

Waveform:2 ch

Lead mode:3 Leads ( R, L, F or RA, LA, LL)

Lead selection:I, II, III,

Waveform:1 ch

HR and Alarm?

Range:?

Adult:15 ~ 300 bpm

Neo/Ped:15 ~ 350 bpm

Accuracy:± 1% or ± 1bpm,which great

Resolution:1 bpm

Sensitivity:> 200 (uV P-P)

Differential Input Impedance:> 5 MΩ

RESPARATION:

Method:Impedance between R-F(RA-LL)

Differential Input Impedance:>2.5 MΩ

Measuring Impedance Range:0.3~5.0Ω

Base line Impedance Range:0 – 2.5 ?KΩ

Bandwidth:0.3 ~ 2.5 Hz

Resp. Rate

Measuring and Alarm Range?

Adult:0 ~ 120 rpm

Neo/Ped:0 ~ 150 rpm

Resolution:1 rpm

Accuracy:±2 rpm

Apean Alarm:10 ~ 40 S

NIBP

Method:Oscillometric

Mode:Manual, Auto, STAT

Measuring Interval in AUTO Mode

?1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)

Measuring Period in STAT Mode:5 Min

Pulse Rate Range:40 ~ 240 bpm

Alarm Type:SYS, DIA, MEAN

Measuring and alarm range:???

Adult Mode

SYS?:40 ~ 270 mmHg

DIA?:10 ~ 215 mmHg

MEAN:20 ~ 235 mmHg

Pediatric Mode

SYS:40 ~ 200 mmHg

DIA:10 ~ 150 mmHg

MEAN:20 ~ 165 mmHg

Neonatal Mode

SYS:40 ~ 135 mmHg

DIA:10 ~ 100 mmHg

MEAN:20 ~ 110 mmHg

Overpressure Protection

Adult Mode:297±3 mmHg

Pediatric Mode:240±3 mmHg

Neonatal Mode:147±3 mmHg

SpO2

Measuring Range:0 ~ 100 %

Alarm Range:0 ~ 100 %

Resolution:1 %

Accuracy:?????

70% ~ 100% ?±2 %

0% ?~ ?69% ?unspecified

Actualization interval:about 1 Sec.

Alarm Delay:10 Sec.

Pulse Rate

Measuring and Alarm Range:0~254bpm

Resolution:1bpm

Accuracy:±2bpm

I.5TEMP measurement:

Channel:1

Measuring and Alarm Range:0 ~ 50?°C

Resolution:0.1°C

Accuracy:±0.1°C

Actualization interval:about 1 Sec.

Average Time Constant:< 10 Sec.

Package List:

1×Dental Patient Monitor

1×EKG Lead wire

1×NIBP Cuff

1×NIBP Extension Cable

1×SpO2 Sensor

1×Temp Sensor

3×Limp Clip

5×Electrode

1×User Manual

?

C.12 Inch Portable Multi-parameter? Vital Sign Patient Monitor ECG NIBP RESP TEMP SPO2 PRDescription:

Portable Multi-parameter?Patient Monitor is adaptable to adult, pediatric and neonatal usage. It can monitor vital signals as ECG, Respiratory Rate, SpO2, NIBP, TEMP and IBP.It integrates parameter measuring modules, display and recorder in one device, featuring in compactness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient.

Features:

12"?high resolution color TFT LCD display.

6 Standard parameters:ECG, RESP, NIBP, SPO2, TEMP, PR.

Can be arbitrarily set the alarm limit, automatic sound and light alarm.

The back of the machine is designed with a storage box, which can put some accessories,convenient?for doctors use.

Drug solubility calculation function, Arrhythmia analysis function.

Built-in lithium battery,AC and DC,can provide long-term monitoring after power failure.

Widely used in the Department of internal medicine, Dental practices (both pediatric and adult), oral surgery centers surgery, operation room,obstetrics and Gynecology, pediatrics, emergency center,ICU,CCU.

Specification:

ECG

Lead Mode:5 Leads (?R, L, F, N, C or RA, LA, LL, RL,V)

Lead selection:I, II, III, avR, avL, avF, V,

Waveform:2 ch

Lead mode:3 Leads ( R, L, F or RA, LA, LL)

Lead selection:I, II, III,

Waveform:1 ch

HR and Alarm?

Range:?

Adult:15 ~ 300 bpm

Neo/Ped:15 ~ 350 bpm

Accuracy:± 1% or ± 1bpm,which great

Resolution:1 bpm

Sensitivity:> 200 (uV P-P)

Differential Input Impedance:> 5 MΩ

RESPARATION:

Method:Impedance between R-F(RA-LL)

Differential Input Impedance:>2.5 MΩ

Measuring Impedance Range:0.3~5.0Ω

Base line Impedance Range:0 – 2.5 ?KΩ

Bandwidth:0.3 ~ 2.5 Hz

Resp. Rate

Measuring and Alarm Range?

Adult:0 ~ 120 rpm

Neo/Ped:0 ~ 150 rpm

Resolution:1 rpm

Accuracy:±2 rpm

Apean Alarm:10 ~ 40 S

NIBP

Method:Oscillometric

Mode:Manual, Auto, STAT

Measuring Interval in AUTO Mode

?1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)

Measuring Period in STAT Mode:5 Min

Pulse Rate Range:40 ~ 240 bpm

Alarm Type:SYS, DIA, MEAN

Measuring and alarm range:???

Adult Mode

SYS?:40 ~ 270 mmHg

DIA?:10 ~ 215 mmHg

MEAN:20 ~ 235 mmHg

Pediatric Mode

SYS:40 ~ 200 mmHg

DIA:10 ~ 150 mmHg

MEAN:20 ~ 165 mmHg

Neonatal Mode

SYS:40 ~ 135 mmHg

DIA:10 ~ 100 mmHg

MEAN:20 ~ 110 mmHg

Overpressure Protection

Adult Mode:297±3 mmHg

Pediatric Mode:240±3 mmHg

Neonatal Mode:147±3 mmHg

SpO2

Measuring Range:0 ~ 100 %

Alarm Range:0 ~ 100 %

Resolution:1 %

Accuracy:?????

70% ~ 100% ?±2 %

0% ?~ ?69% ?unspecified

Actualization interval:about 1 Sec.

Alarm Delay:10 Sec.

Pulse Rate

Measuring and Alarm Range:0~254bpm

Resolution:1bpm

Accuracy:±2bpm

I.5TEMP measurement:

Channel:1

Measuring and Alarm Range:0 ~ 50?°C

Resolution:0.1°C

Accuracy:±0.1°C

Actualization interval:about 1 Sec.

Average Time Constant:< 10 Sec.

Package List:

1×Patient Monitor

1×EKG Lead wire

1×NIBP Cuff

1×NIBP Extension Cable

1×SpO2 Sensor

1×Temp Sensor

1×Ground Cable

5×Electrode

2×Fuse

1×User Manual(CD)

?

D.Portable 12'' Medical Patient Monitor Vital Sign ICU ECG NIBP RESP TEMP PR SPO2?Features:?Ergonomic design, portable, convenient for use
12" TFT display, configurasble up to 8 waveforms, enables maximum data visibility for the most critical parameters
Unique digital SPO2 technology can work accurate during motion and low perfusion
Anti AC & high-frequency electrosurgical & defibrillator’s interference
Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others
Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events
ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation
Audible & visual alarm available, adjustable
Patient information management function
Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room
Optional software upgrading based on USB
Wired/wireless networking with central monitoring system, up to?64 beds in one group
Built-in 3 trace thermal recorder for printing real-time and historical data
Multi-language i.e. English, Spanish, Turkish.
Super long life rechargeable Lithium battery upto 4 hours of working time
Suitable for adult, pediatrics and neonate patients
?
Standard configuration:????????????
ECG, NIBP, SPO2, TEMP, RESP, PR, Rechargeable Lithium lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width: 0.05Hz-100Hz(3dB)
Heart rate:?
Scope: 15 times/minute to 300 times/minutes
Accuracy:? ±1 time/minute
Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.?
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.???
Accuracy: Error rate < 20%?????????
Undetected rate < 20%?
ST section?
Scope:???? ±0.8mV
Precision :? < ±0.05mV
SpO2
Detection scope:? ?0%-100%
Accuracy???????? ±1%???? ?±2%????? 70%-89%?NIBP?
Theory Electric oscillator?
Cuff gassing time?? less than 15 seconds
First-time gassing pressure: dynamic state 24kPa(180 mmHg)
Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg)
18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg),
Automatic detection period: 1 minute to 240 minutes?
Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m
in -90min) and 30min(90 min -240min)
Detection scope:?
Systolic blood pressure:?? 4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure???????????? 2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure?????????????? 2.7kPa~31.3kPa?????? (20mmHg~235mmHg)
Detection accuracy?
Static pressure: ±3mmHg
Pulse rate: ?±2%Resp
Chest impedance method or concentration of carbon dioxide at end of respiration?
Scope of chest impedance method???? 0 time/minute – 100 minutes/minute?
Precision of chest impedance method? time/minute?
Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby)
Detection precision of respiration rate: ±1 time/minute?Temp
Single/double path?
Type:??? Vascular/surface temperature?
Scope:??? 20℃~50℃
Accuracy:? ±0.2℃
Single/double path?
Type: direct and continuous detection?
Scope: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg)? 13.33k
Pa(100mmHg) above ±2%
Frequency response:DC-12Hz
Input resistance: not less than 500k?
Sensitivity of sensor: 5μV/V/mmHg
Motivation voltage:5V (DC)
Accuracy of sensor: ±2%Isolation voltage: 4 kV??E.8 Inch ICU CCU Vital Sign Patient Monitor 6 parameter ECG NIBP RESP TEMP SPO2 PRDescription:

Portable Patient Monitor is adaptable to adult, pediatric and neonatal usage. It can monitor vital signals as ECG, Respiratory Rate, SpO2, NIBP, TEMP and IBP. It integrates parameter measuring modules, display and recorder in one device, featuring in compactness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient. Large high-resolution display provides clear view of 5 waveforms and full monitoring parameters.

Features:

8 inch TFT color screen

Exquisite design suitable to moving operation?

Various interfaces: standard screen, trend screen, oxyCRG screen, NIBP list screen, big front screen.

Real-time S-T segment analysis, pace-maker detection.?

Built-in rechargeable lithium battery,?convenient for patient? moving.

Suitable for adult, pediatric and neonatal patient

Standard Configuration:

SpO2, PR, NIBP, ECG, RESP, TEMP

Technical Parameters:

ECG:

Lead Mode:5 Leads (?R, L, F, N, C or RA, LA, LL, RL,V)

Lead selection:I, II, III, avR, avL, avF, V,

Waveform:2 ch

Gain:2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV

Heart Rate:15-300BPM(Adult) 15-350BPM(Neonatal)

Accuracy:± 1% or ± 1bpm,which great

Resolution:1 bpm

ST measurement Range:-2.0-+2.0mV

Sweep Speed:12.5 mm/s,25mm/s,50mm/s

Alarm:Available

Review:Available

RESP:

Method Impedance between R-F(RA-LL)

Measuring Range:Adult??0 ~ 120 rpm,Neo/Ped 0 ~ 150 rpm

Resolution:1 rpm

Accuracy:±2 rpm

NIBP:

Method:Oscillometric

Mode:Manual, Auto, STAT

Measuring and alarm range???

Adult Mode

SYS:40 ~ 270 mmHg

DIA:10 ~ 215 mmHg

MEAN:20 ~ 235 mmHg

Pediatric Mode

SYS:40 ~ 200 mmHg

DIA:10 ~ 150 mmHg

MEAN:20 ~ 165 mmHg

Neonatal Mode

SYS:40 ~ 135 mmHg

DIA:10 ~ 100 mmHg

MEAN:20 ~ 110 mmHg

Resolution:1mmHg

Accuracy:+-5mmHg

SpO2:

Measuring Range:0 ~ 100 %

Alarm Range:0 ~ 100 %

Resolution:1 %

Accuracy:70% ~ 100% ?±2 %

Actualization interval:about 1 Sec.

Alarm Delay:10 Sec.

Pulse Rate :0~254bpm

Resolution:1bpm

Accuracy:±2bpm

Temperature:

Measuring and Alarm Range:0 ~ 50 C

Resolution:0.1C

Accuracy:0.1C

Actualization interval:about 1 Sec.

Average Time Constant:< 10 Sec.

Package List:

Patient monitor

Temperature probe

ECG lead cable

ECG electrode

Adult NIBP cuff

NIBP extension tube

Adult fingertip SpO2 probe

Power cord

User Manual

?

F.Handheld 6-Parameter Vital sign Monitor Patient Monitor ECG NIBP Spo2 Pulse Rate Temperature.
G.Vet Multi-Parameter Veterinary Patient Monitor NIBP SPO2 ECG TEMP RESP PR Vital Signs ICU CCU Patient MonitorDescription:

This monitor is suitable for felines,canines and other animals, may monitor the physical parameters, such as electrocardiograph (ECG), noninvasive blood pressure (NIBP), oxygen saturation (SpO?), respiration rate (Resp), body temperature (Temp) and so on, can display maximum 8 waveforms and all information of the parameters monitored in the same screen.

Features:

Ergonomic design, Lightweight, compact and portable, convenient for use.??

12" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters

Unique digital SPO2 technology can work accurate during motion and low perfusion.??

Anti AC & high-frequency electrosurgical?& defibrillator’s interference.

Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and other??Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events

ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation.Audible & visual alarm available, adjustable.Super long life rechargeable Lithium battery up to 4 hours of working time?This monitor provides the function of computation for 21 kinds of medicines and the titration table.
It is providing fast and reliable measurements for the veterinary patients. The measuring size of patients animals range from the small to big animals such as cats dogs, horses. It is suitable for vet hospital, clinic, and animal labs.
Standard configuration:?????????????ECG, NIBP, SPO2, TEMP, RESP, PR, Rechargeable Lithium battery.
ECG:Full lead: I, II, III, AVL, AVR, AVF, V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV?Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s?Band width: 0.05Hz-100Hz(3dB)
Heart rate:?Scope: 15 times/minute to 300 times/minutes
Accuracy:?±1 time/minute?Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.?
Accuracy: Error rate < 20%?Undetected rate < 20%???ST sectionScope: ±0.8mV?Precision :?< ±0.05mVSpO2:
Detection scope: 0%-100%Accuracy:±1% 90%-100%;±2% 70%-89%?

NIBP:

Theory Electric oscillator

Manual selection:9.3kPa(70 mmHg),13.3kPa(100 mmHg)16.0kPa(120 mmHg)

18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg),Automatic detection period:1 minute to 240 minutes.

Detection accuracy:

Static pressure: ±3mmHgPulse rate: ±2%?

Respiration Rate:

Measurement Range:0 ~ 150 BrPM?

Resolution:1 BrPM

Accuracy:0~6 BrPM: unspecified;7~150 BrPM:?±2 BrPM?

Temperature:

Channel:2

Measure and Alarm Range:0 ~ 50℃

Accuracy(no sensor):±?0.1℃(0℃ –?50℃)

Environment Specification:???Operating Temp: 0 to 05°cStorage Temp: -20 to +50°c?Relative Humidity: 15 to 95%(Operating), 15 to 95%(Storage)Power Supply:100~240 VAC, 50/60 Hz, Pmax=90VA Fuse T1.5A?

?

?

Payment
We will ship out the item after receiving cleared payment.
Shipping
A complete and correct shipping address is essential.
Customers with shipping addresses outside of the U.S. are responsible for all duties and import taxes. Please contact your customs for information
Return Policy
?All items are in brand new condition unless specified.
FDA declaration:

The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not offer on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.(Seller name: Bob Xu?? City: Beijing??Country: China???Phone : +86 18081886519)

This item has been cleaned and treated according to the manufacturer's instructions.

The?Powered Surgical Instrument / Speed 808 System is certified with the US FDA 510(k) Number:K132989

The?Powered Surgical Instrument / Hair Remove Device?is certified with the US FDA 510(k) Number:K180353

The?Powered Surgical Instrument / Hair Remove System?is certified with the US FDA 510(k) Number:K141973

massager, vacuum, light induced heating / Slimming Treatment Device is certified with the US FDA?510(k) Number:K161892

Our products are CE/FDA Approve

?



Buy Now

Patient Aid Portable Medical Grade Floor Scale, 12

Patient Aid Portable Medical Grade Floor Scale, 12"x12.5" - Up to 550lb

$40.99



Portable Emergency Dental Phlegm Suction Unit Medical Vacuum Aspirator Machine picture

Portable Emergency Dental Phlegm Suction Unit Medical Vacuum Aspirator Machine

$170.57



Portable Suction Unit Machine Medical Aspirator Homecare Tabletop Phlegm Mucus picture

Portable Suction Unit Machine Medical Aspirator Homecare Tabletop Phlegm Mucus

$137.66



Popular Tutorials

Alarms and Indicator Circuit diagrams Audio electronic circuits list Circuits for Cars/Motorcycles Computer/PC Hardware Circuits : Design Ideas : Fun/Games Circuits : Signal/Sequence/Misc. Generators : Home/Garden related Circuits : Lights & LED Circuits : Motor Circuits : Music related Circuits : < Oscillator Circuits : Power Supply (PS) Circuit diagrams : Radio,transmitter,receiver circuits : Remote Control Circuit diagrams : Robotics related Circuits : Sensors : Telephone Circuit diagrams : Test & Measurement Circuits :